Bicycle spaces, showers and change rooms are set by Clause 52.34 (Bicycle facilities) of the Victoria Planning Provisions. Check the current version in your council’s planning scheme. Find them late and they compete with car parking, bin rooms and services for the same ground floor or basement. Enter your uses to estimate what the clause asks for, with the working shown.
Add each use in the development and enter its size. For an extension, enter only the increased floor area (Clause 52.34-1).
[Space size · should]
Bicycle spaces should provide at least 1.7 m long, 1.2 m high and 0.7 m wide at the handlebars (52.34-6).
[Ride-in distance · should]
Bicycle spaces should be located so a bicycle can be ridden to within 30 m of them (52.34-6).
[Compound path · must]
A bicycle compound must provide an internal access path at least 1.5 m wide (52.34-6).
[Signage · should]
Signage should be at least 0.3 m wide and 0.45 m high, with a white bicycle on a blue background (52.34-7).
Employee and resident spaces go in a bicycle locker or at a rail in a lockable compound. Visitor, shopper and student spaces go at a bicycle rail (52.34-5).
Only the uses listed in column 1 of Table 1 to Clause 52.34-5. The requirement for a use is the sum of the employee/resident column and the visitor/shopper/student column. Some rates only apply above a size: dwellings and residential buildings in developments of four or more storeys, and offices and shops over 1,000 sq m. Restaurant visitor spaces have a 400 sq m threshold. The clause can be read as needing no visitor spaces at or below 400 sq m, or as needing at least 2. We show both results. A Precinct Zone schedule can set numbers for other uses too.
The clause says: “If in calculating the number of bicycle facilities the result is not a whole number, the required number of bicycle facilities is the nearest whole number. If the fraction is one-half, the requirement is the next whole number.” So 2.4 becomes 2 and 2.5 becomes 3.
Table 2 requires showers “If 5 or more employee bicycle spaces are required, 1 shower for the first 5 employee bicycle spaces, plus 1 to each 10 employee bicycle spaces thereafter.” Table 3 requires “1 change room or direct access to a communal change room to each shower.” The change room can be combined with the shower. Visitors need none. The calculator lets you count showers two ways. Pooled across uses (the starting setting) counts employee spaces for the whole site together; it relies on shared facilities, which the responsible authority may need to accept (Clauses 52.34-2 and 52.34-4). Per use works out showers for each use separately, which is how the clause reads. Pooling can give more or fewer showers than per use, so the result shows both figures.
Where the floor area of an existing use increases, the requirement applies only to the increased floor area (Clause 52.34-1). The clause does not say whether the 1,000 sq m (office, shop) and 400 sq m (restaurant) thresholds are tested on the increase or on the total area. Tick “This is an extension to an existing use” and the result shows both: the threshold tested on the increased floor area only, and on the total floor area after the extension. In both, the rate applies to the increased floor area only. Confirm with council.
Yes, by planning permit. Clause 52.34-2 allows a permit to vary, reduce or waive the requirements, and Clause 52.34-4 lists what the responsible authority must consider, such as the location, the users of the land, and whether facilities can be shared between uses.
We checked the Hume Planning Scheme text against the Victoria Planning Provisions on 17 November 2026 and found them identical. Check your own council’s scheme and any Precinct Zone schedule.
Indicative only. This is not advice and not a statement that a proposal complies. The responsible authority decides the requirement, and a permit may vary, reduce or waive it (Clause 52.34-2). Results do not account for Precinct Zone schedules, how council classifies the use, or later amendments. Check the current planning scheme and confirm with council or a qualified consultant.
Clause 52.34-5 as last amended by VC274 (28 February 2025), checked 17 November 2026.